रेल डिपार्टमेंटल तैयारीRail Departmental Taiyari — रेलवे विभागीय परीक्षाओं की तैयारीLogin / Open app

Electric Circuits and Measurements

Electrical Engineering — General (Part I) • Part 1 / 4 • AEE (विद्युत) full part free

हिंदी में पढ़ें

In this part

  1. DC Circuits and Theorems
  2. AC Circuits
  3. Three-phase Circuits
  4. Measurements
Basic sources

Standard material on electric circuits and measurements; Indian Standards (energy meters, CT/PT). Solved examples with formulas — calculation questions in the exam come in exactly these types.

1DC Circuits and Theorems

In simple words

Ohm's law (V = IR) and the theorems for solving circuits — series/parallel resistance, Kirchhoff, etc.

Example

Vth = 24 V, Rth = 4 Ω — for maximum power RL = 4 Ω; Pmax = 24² ÷ 16 = 36 W.

2AC Circuits

In simple words

AC circuits — reactance, impedance and the power factor (cos φ).

Formula

XL = 2πfL; XC = 1 ÷ (2πfC); Z = √(R² + (XL − XC)²); cos φ = R ÷ Z

Formula

Active power P = VI cos φ (W); reactive Q = VI sin φ (VAR); apparent S = VI (VA); S² = P² + Q²

Example

R = 30 Ω and XL = 40 Ω in series at 230 V, 50 Hz.
Z = √(30² + 40²) = 50 Ω; I = 230 ÷ 50 = 4.6 A; cos φ = 30 ÷ 50 = 0.6 (lagging); P = 230 × 4.6 × 0.6 ≈ 635 W; Q = 230 × 4.6 × 0.8 ≈ 846 VAR.

3Three-phase Circuits

In simple words

Star and delta connections in three-phase — the relation between line and phase values (√3).

Summary table

Connection Voltage Current
Star (Y) VL = √3 Vph IL = Iph
Delta (Δ) VL = Vph IL = √3 Iph
Formula

Total power P = √3 VL IL cos φ; two-wattmeter method: P = W₁ + W₂, tan φ = √3 (W₁ − W₂) ÷ (W₁ + W₂)

Example

A 415 V three-phase motor of 10 kW at 0.8 pf. Line current = 10,000 ÷ (1.732 × 415 × 0.8) ≈ 17.4 A.

4Measurements

In simple words

Measuring instruments — which works on DC, AC or both.

Remember

Quick revision —

  • Maximum power: RL = Rth, P = V²/4R, efficiency 50%.
  • Z = √(R² + X²); pf = R/Z; S² = P² + Q²; resonance f = 1/2π√LC.
  • Star: VL = √3 Vph; delta: IL = √3 Iph; P = √3 VLIL cos φ.
  • CT secondary never open; Megger — insulation; Kelvin — very low resistance.
Exam trap
  • Efficiency at maximum power transfer is 50% (RL = Rth).
  • Star: VL = √3 Vph (IL = Iph); delta: IL = √3 Iph (VL = Vph).
  • Never leave the secondary of a CT open.
Full preparation in the app

All parts in Hindi + English, subject-wise MCQs and mock tests — create a free account.

Start free
All parts — Electrical Engineering — General (Part I)
All exams & subjects (Hindi) • Login • शिक्षक भर्ती (RPSC / REET) नोट्स • Telegram channel • गोपनीयता नीति • नियम व शर्तें • संपर्क