Basic sourcesStandard material on electric circuits and measurements; Indian Standards (energy meters, CT/PT). Solved examples with formulas — calculation questions in the exam come in exactly these types.
1DC Circuits and Theorems
In simple wordsOhm's law (V = IR) and the theorems for solving circuits — series/parallel resistance, Kirchhoff, etc.
- Ohm's law V = IR; in series R = R₁ + R₂…; in parallel 1/R = 1/R₁ + 1/R₂…; power P = VI = I²R = V²/R.
- Kirchhoff: KCL — the sum of currents at a node is zero; KVL — the sum of voltages around a closed loop is zero.
- Thevenin: any linear network = Vth (open-circuit voltage) in series with Rth; Norton: IN in parallel with RN (= Rth). Superposition: adding the effect of each source one at a time.
- Maximum power transfer: at load RL = Rth; then Pmax = Vth² ÷ 4Rth (efficiency only 50%).
ExampleVth = 24 V, Rth = 4 Ω — for maximum power RL = 4 Ω; Pmax = 24² ÷ 16 = 36 W.
2AC Circuits
In simple wordsAC circuits — reactance, impedance and the power factor (cos φ).
FormulaXL = 2πfL; XC = 1 ÷ (2πfC); Z = √(R² + (XL − XC)²); cos φ = R ÷ Z
FormulaActive power P = VI cos φ (W); reactive Q = VI sin φ (VAR); apparent S = VI (VA); S² = P² + Q²
- RMS value = peak ÷ √2 (sine wave); average = 0.637 × peak.
- Resonance (series RLC): XL = XC, fr = 1 ÷ 2π√(LC); impedance minimum = R, current maximum, pf = 1.
- Disadvantages of a low power factor: more current for the same power → more I²R loss, larger cables/transformers, voltage drop, penalty from the electricity board.
ExampleR = 30 Ω and XL = 40 Ω in series at 230 V, 50 Hz.
Z = √(30² + 40²) = 50 Ω; I = 230 ÷ 50 = 4.6 A; cos φ = 30 ÷ 50 = 0.6 (lagging); P = 230 × 4.6 × 0.6 ≈ 635 W; Q = 230 × 4.6 × 0.8 ≈ 846 VAR.
3Three-phase Circuits
In simple wordsStar and delta connections in three-phase — the relation between line and phase values (√3).
Summary table
| Connection | Voltage | Current |
|---|---|---|
| Star (Y) | VL = √3 Vph | IL = Iph |
| Delta (Δ) | VL = Vph | IL = √3 Iph |
FormulaTotal power P = √3 VL IL cos φ; two-wattmeter method: P = W₁ + W₂, tan φ = √3 (W₁ − W₂) ÷ (W₁ + W₂)
ExampleA 415 V three-phase motor of 10 kW at 0.8 pf. Line current = 10,000 ÷ (1.732 × 415 × 0.8) ≈ 17.4 A.
4Measurements
In simple wordsMeasuring instruments — which works on DC, AC or both.
- Instruments: PMMC (DC only, linear scale), moving iron (AC/DC), electrodynamometer (wattmeter), digital multimeter; energy meters — static (electronic), smart meters.
- CT and PT: bring large currents/voltages to a measurable level — never leave the secondary of a CT open (a high voltage develops and is dangerous); the secondary of a PT must not be short-circuited.
- Megger — insulation resistance; earth tester — earth resistance; clamp meter — current without breaking the circuit; power analyser — pf, harmonics.
- Bridges: Wheatstone (medium resistance), Kelvin double (very low resistance), Maxwell/Hay (inductance), Schering (capacitance).
RememberQuick revision —
- Maximum power: RL = Rth, P = V²/4R, efficiency 50%.
- Z = √(R² + X²); pf = R/Z; S² = P² + Q²; resonance f = 1/2π√LC.
- Star: VL = √3 Vph; delta: IL = √3 Iph; P = √3 VLIL cos φ.
- CT secondary never open; Megger — insulation; Kelvin — very low resistance.
Exam trap
- Efficiency at maximum power transfer is 50% (RL = Rth).
- Star: VL = √3 Vph (IL = Iph); delta: IL = √3 Iph (VL = Vph).
- Never leave the secondary of a CT open.